Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Don't get GSW? Talk to your librarian.
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; January 1960; v. 50; no. 1; p. 135-151
© 1960 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by POMEROY, P. W.
Right arrow Articles by SUTTON, G. H.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

The use of galvanometers as band-rejection filters in electromagnetic seismographs

PAUL W. POMEROY and GEORGE H. SUTTON

LAMONT GEOLOGICAL OBSERVATORY, COLUMBIA UNIVERSITY,, PALISADES, NEW YORK

Abstract

The large-amplitude intermediate-period, 4-9 seconds, microseisms are effectively removed from high-magnification long-period seismograms with maximum magnification near 50 seconds period. This has been accomplished by the use of a galvanometer of natural period in the microseism range as a band-rejection filter. Addition of the filter galvanometer greatly increases the usefulness of these instruments for studies of long-period microseisms and for clear detection and resolution of the long-period components of both body and surface waves from small shocks at very great distances. Magnification equations and theoretical magnification curves show that extremely high sensitivities for desired periods and low sensitivities for undesired periods can be obtained by combining one or more filter galvanometers in seismograph systems, varying the damping constants and natural periods of the components, and varying the coupling between the components. Also, by proper choice of instrument parameters, undesired periods can be rejected without appreciable modification of the seismograph magnification for periods outside the rejection band.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
H. JAROSCH and A. R. CURTIS
A note on the calibration of the electromagnetic seismograph
Bulletin of the Seismological Society of America, June 1, 1973; 63(3): 1145 - 1155.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
J. CL. DE BREMAECKER
Detection of small arrivals
Bulletin of the Seismological Society of America, December 1, 1964; 54(6B): 2141 - 2163.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
S. DOPP
Application of communication network theory to the electromagnetic seismograph
Bulletin of the Seismological Society of America, October 1, 1964; 54(5A): 1479 - 1489.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
J. OLIVER and R. PAGE
Concurrent storms of long and ultralong period microseisms
Bulletin of the Seismological Society of America, January 1, 1963; 53(1): 15 - 26.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
A. F. ESPINOSA, G. H. SUTTON, and H. J. MILLER
A transient technique for seismograph calibration
Bulletin of the Seismological Society of America, October 1, 1962; 52(4): 767 - 779.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
J. CL. DE BREMAECKER, P. DONOHO, and J. G. Michel
A direct digitizing seismograph
Bulletin of the Seismological Society of America, July 1, 1962; 52(3): 661 - 672.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
C. J. BYRNE
Instrument noise in seismometers
Bulletin of the Seismological Society of America, January 1, 1961; 51(1): 69 - 84.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America