Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Email Content Delivery
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; October 1968; v. 58; no. 5; p. 1379-1383
© 1968 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HADE, G.
Right arrow Articles by KUO, J. T.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Laser interferometer calibration system for extensometers

G. HADE, M. CONNER and J. T. KUO

LAMONT GEOLOGICAL OBSERVATORY COLUMBIA UNIVERSITY, PALISADES, NEW YORK 10964

Abstract

A laser interferometer technique has been developed for calibrating extensometers at the Ogdensberg Station of Lamont Geological Observatory. It provides remotecontrolled calibration of both horizontal and vertical extensometers within the linear range of the transducer output.

The present calibration system consists of an electromagnetic driving unit and a Michelson interferometer. The transducer end of the extensometer is displaced longitudinally with an electromagnetic driving unit, which is excited by a variable low-frequency oscillator with a bandwidth of 0.0005 to 60 kHz. The resultant displacement is detected by counting fringe displacements of the interferometer with an Ne-He laser source. With this calibration system, motion as small as 0.03 micron can be determined with excellent repeatability and with errors of less than 5 per cent, in comparison with errors of more than 40 per cent for the optical calibration method previously used.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
C. BEAUMONT and J. BERGER
An analysis of tidal strain observations from the United States of America: I. The laterally homogeneous tide
Bulletin of the Seismological Society of America, December 1, 1975; 65(6): 1613 - 1629.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America