Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Signup for GSW Email News
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; October 1968; v. 58; no. 5; p. 1621-1630
© 1968 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by RUSSELL, R. D.
Right arrow Articles by JENSEN, O. G.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

The Maxwell bridge as a circuit element in electromagnetic feedback seismographs

R. D. RUSSELL, R. D. MELDRUM and O. G. JENSEN

DEPARTMENT OF GEOPHYSICS THE UNIVERSITY OF BRITISH COLUMBIA, VANCOUVER, Canada

Abstract

The characteristics of a seismograph can be modified by the use of filters or by the application of negative feedback. Both methods provide the same basic signal to noise capabilities, and each has its particular advantages. The principal advantage of the feedback instrument is its flexibility and the possibility of linearity over a greater dynamic range.

The application of electrical feedback to a seismometer requires the creation of normally nonexistent electrical input terminals. By incorporating the seismometer into a balanced Maxwell impedance bridge, input terminals can be simulated and the feedback introduced through the bridge. With the use of such negative feedback, it is possible to control individually the effective mass, spring and damping constants of a seismometer. One instrument can thereby simulate seismometers of very different mechanical properties. For example, it is possible to increase the effective mass of a Willmore Mark I seismometer to well over one ton.

A feedback seismograph has been constructed using these principles and has been in continuous operation for nearly two years.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
M. D. BURKE, E. R. KANASEWICH, J. D. MALINSKY, and J. F. MONTALBETTI
A wide-band digital seismograph system
Bulletin of the Seismological Society of America, October 1, 1970; 60(5): 1417 - 1424.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America