Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Don't get GSW? Talk to your librarian.
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; April 1975; v. 65; no. 2; p. 411-424
© 1975 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MITRONOVAS, W.
Right arrow Articles by WIELANDT, E.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

High-precision phase calibration of long-period electromagnetic seismographs

W. MITRONOVAS and E. WIELANDT

INSTITUT FÜR GEOPHYSIK ETH-AUSSENSTATION HÖNGGERBERG, CH-8049 ZURICH, Switzerland

Abstract

A modification of the steady-state (direct) calibration method is described where-by the phase response of a long-period seismograph system can be determined with a precision at least one order of magnitude higher than has been reported in the literature so far. In a period range of 5 to 200 sec this means determining the time delay of a system to within ±0.05 sec or better. An improvement is also suggested in the method to determine the system parameters from which the phase can be calculated theoretically. The improvement consists in the ability to reduce any bias in the estimate of the parameters. A comparison between the improved versions of the steady-state (direct) and parameter (indirect) methods indicates that for certain seismograph systems the agreement in the phase delay can be within 0.1 sec but for others the difference can be more than 0.5 sec. The difference apparently results from the fact that certain seismometers are not ideal instruments and cannot be represented by theoretical parameters exactly, rather than from any bias in the two methods of calibration. In addition, the steady-state method is used to study the temperature effect on the phase response of two types of long-period systems: (a) a conventional seismometer-galvanometer system and (b) a new seismometer-electronic amplifier-filter system. It was found that, in a period range of 5 to 200 sec, a change in temperature of 8°C causes a change in phase delay of about 0.4 sec for the first system and only 0.05 sec for the second system.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
R. G. DANIEL
An intermediate-period field system using a short-period seismometer
Bulletin of the Seismological Society of America, October 1, 1979; 69(5): 1623 - 1626.
[PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
W. MITRONOVAS
Temperature effects on long-period seismographs: an accurate method to determine the transfer function
Bulletin of the Seismological Society of America, August 1, 1976; 66(4): 1405 - 1412.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
E. BERG and D. M. CHESLEY
Automated high-precision amplitude and phase calibration of seismic systems
Bulletin of the Seismological Society of America, August 1, 1976; 66(4): 1413 - 1424.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
E. WIELANDT and W. MITRONOVAS
An electronic long-period seismograph for surface-wave dispersion studies
Bulletin of the Seismological Society of America, June 1, 1976; 66(3): 987 - 996.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
W. MITRONOVAS
Accuracy in phase determination of LP electromagnetic seismographs based on transient calibration pulse
Bulletin of the Seismological Society of America, February 1, 1976; 66(1): 97 - 104.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America