Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Don't get GSW? Talk to your librarian.
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; August 1975; v. 65; no. 4; p. 937-949
© 1975 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BOLT, B. A.
Right arrow Articles by SOZEN, M. A.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

The study of earthquake questions related to Veterans Administration hospital facilities

B. A. BOLT, R. G. JOHNSTON, J. LEFTER and M. A. SOZEN

SEISMOGRAPHIC STATION UNIVERSITY OF CALIFORNIA, BERKELEY, CALIFORNIA
BRANDOW & JOHNSTON ASSOC. CONSULTING STRUCTURAL ENGINEERS, LOS ANGELES, CALIFORNIA
CIVIL ENGINEERING SERVICES VETERANS ADMINISTRATION, WASHINGTON, D.C.
DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF ILLINOIS, URBANA, ILLINOIS

Abstract

After the San Fernando earthquake, February 9, 1971, the Veterans Administration undertook investigations and research to develop requirements for earthquake-resistant design for VA hospital facilities. Veterans Administration hospital sites number 170 across the United States. Site-evaluation procedures and design criteria have now been developed. Evaluations of peak ground accelerations for engineering assessments at hospital sites in zones 3 and 2 are available. In a parallel strong-motion recording program, 58 accelerometers already have been placed in VA hospital facilities across the country. Attention has been given to operations, utilities and access after destructive earthquakes, particularly emergency services that must serve the hospitals' own patients and community. Standards for protection of nonstructural elements and equipment of hospitals have been established.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
B. MOHRAZ
A study of earthquake response spectra for different geological conditions
Bulletin of the Seismological Society of America, June 1, 1976; 66(3): 915 - 935.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America