Bulletin of the Seismological Society of America; August 1976; v. 66; no. 4; p. 1413-1424
© 1976 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BERG, E.
Right arrow Articles by CHESLEY, D. M.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Automated high-precision amplitude and phase calibration of seismic systems

EDUARD BERG and DUNCAN M. CHESLEY

HAWAII INSTITUTE OF GEOPHYSICS UNIVERSITY OF HAWAII, HONOLULU, HAWAII 96822

Abstract

Automated amplitude and phase response of the complete seismometer-recording system is obtained from step inputs to the calibration coil. High accuracy is achieved by summing as many pulses as desired (to eliminate background noise) by a correlation technique and subsequent Fourier analysis. The only parameters required are the seismometer mass, the Cal-coil constant (referred to the center of mass if appropriate) and current, and the precise onset time of one reference calibration current, which are all very stable over long time periods. Application to the High-Gain Long-Period system at KIP yields the magnification curve from only six pulses with less scatter (< ± 5 per cent for periods larger than 20 sec) than routine steady-state calibrations.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
P. W. Rodgers, A. J. Martin, M. C. Robertson, M. M. Hsu, and D. B. Harris
Signal-coil calibration of electromagnetic seismometers
Bulletin of the Seismological Society of America, June 1, 1995; 85(3): 845 - 850.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
M. C. CHAPMAN, J. A. SNOKE, and G. A. BOLLINGER
A procedure for calibrating short-period telemetered seismograph systems
Bulletin of the Seismological Society of America, December 1, 1988; 78(6): 2077 - 2088.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
J. REVENAUGH and T. H. JORDAN
Observations of first-order mantle reverberations
Bulletin of the Seismological Society of America, October 1, 1987; 77(5): 1704 - 1717.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS