Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
Bulletin of the Seismological Society of America Signup for GSW Email News
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Bulletin of the Seismological Society of America; February 1983; v. 73; no. 1; p. 143-155
© 1983 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by FENG, C.-C.
Right arrow Articles by TENG, T.-L.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

An error analysis of frequency-time analysis

CHI-CHIN FENG* and TA-LIANG TENG

DEPARTMENT OF GEOLOGICAL SCIENCES UNIVERSITY OF SOUTHERN CALIFORNIA, LOS ANGELES, CALIFORNIA 90089

Abstract

The temporal resolution and accuracy of frequency-time analysis (FTAN) as applied to surface-wave dispersion analysis are examined for a period range from 10 to 200 sec. The constant relative bandwidth filter (Dziewonski et al., 1969), optimum bandwidth filter (Inston et al., 1971), and display-equalized filter (Nyman and Landisman, 1977) are carefully examined with respect to their adequacy of application over a broad period range. Among these Gaussian filters, the optimum bandwidth filter gives a better performance for relatively short-period (less than 50 sec) dispersion measurement. To measure surface-wave dispersion for a broad period range, a "matched-filter FTAN" technique is introduced by modifying the "residual dispersion measurement" technique (Dziewonski et al., 1972). A detailed numerical analysis is made on this new technique; the result demonstrates a significant improvement on both the resolution and the accuracy of surface-wave dispersion data extraction over a broad period range up to at least 200 sec.

Footnotes

* Present address: Shell Oil Company, P.O. Box 527, Houston, Texas 77001.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
Y. ZENG, T.-L. TENG, and K. AKI
Surface-wave mapping of the crust and upper mantle in the Arctic region
Bulletin of the Seismological Society of America, October 1, 1989; 79(5): 1520 - 1541.
[Abstract] [PDF]




JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Seismological Society of America